• Flow-diverter stents for endovascular management of non-fetal posterior communicating artery aneurysms-analysis on aneurysm occlusion, vessel patency, and patient outcome

      Kuhn, Anna L.; Dabus, Guilherme; Kan, Peter; Wakhloo, Ajay K.; Puri, Ajit S. (2018-02-22)
      Background Use of flow-diversion technology in the treatment of incidental and recanalized posterior communicating artery (PComA) aneurysms. Methods Patients treated with the Pipeline embolization device (PED) for PComA aneurysms were identified and included in our retrospective analysis. We evaluated aneurysm characteristics, modified Rankin Scale score (mRS) on admission, angiography follow-up, and patient clinical outcome at discharge, at three to nine months, and at 12-18 months. Results We included 56 patients with a mean age of 56 years. Median mRS on admission was 0. All aneurysms involved the PComA and were either new findings or found to have shown recanalization at angiography follow-up from previous coil embolization or surgical clipping. Intraprocedural device foreshortening was observed in one case requiring additional placement of a self-expanding stent. One intraprocedural aneurysm rupture occurred because of a broken distal wire. This patient had an mRS of 4 after the procedure. Three- to nine-month and 12- to 18-month follow-up angiography showed near complete or complete aneurysm occlusion in most cases. Minimal to mild intimal hyperplasia was seen in five cases at three to nine months. PComA patency over time showed 29 of 46 initially patent vessels still patent at six months. Thirteen and seven PComAs showed progressive decrease in flow at three to nine months and 12-18 months, respectively. Median mRS remained 0 for all patients at three- to nine-month and 12- to 18-month follow-up. Conclusions Our preliminary results show that flow-diversion technology is an effective and safe treatment option. Larger studies with long-term follow-up are needed to validate our promising results.
    • Impact of age on cerebral aneurysm occlusion after flow diversion

      Kuhn, Anna Luisa; Kan, Peter; Henninger, Nils; Srinivasan, Visish; de Macedo Rodrigues, Katyucia; Wakhloo, Ajay K.; Gounis, Matthew J.; Puri, Ajit S. (2019-07-01)
      The purpose of this study was to evaluate safety and efficacy of the pipeline embolization device (PED) in different patient age groups with unruptured intracranial aneurysms (UIA). All patients with UIA treated with the PED between 2011 and 2017 were included. Based on their age, patients were trichotomized to: young ( < /=45years), middle-aged (46 to < 65years) and older ( > /=65years) groups. Patient's vascular risk factors, presenting symptoms and mRS on admission were collected. Follow-up imaging was evaluated for presence/absence of aneurysm occlusion. Clinical outcome at discharge, 3-9months and 12-18months was also documented when available. A total of 260 patients harboring 307 aneurysms (young=57, middle-age=144 and older age group=64). Most aneurysms were located in the anterior circulation (94.8%). Overall morbidity and mortality was 2.3% each (6/260). At 3-9 months near complete to complete aneurysm occlusion was 82.5% (47/57) in the young age group, 82.6% (100/121) in the middle age, and 70.2% (40/57) in the older age group. At 12-18-month, near complete to complete occlusion was 100% in the young age group (32/32), 91.4% (64/70) in the middle age, and 78.4% (29/37) in the older age group. After adjustment for potential confounders, older age patients less frequently achieved near complete to complete occlusion by 3 years than younger subjects (p=0.009, HR 1.34 95%, CI 1.08-1.66). Our results indicate feasibility and safety of PED across different age groups. Further study is required to determine age-related factors relating to aneurysm occlusion after PED to improve outcome and patient counseling.
    • Intraoperative Aneurysm Rupture during Resection for Presumed Metastasis

      Kuhn, Anna L.; de Macedo Rodrigues, Katyucia; Puri, Ajit S. (2019-08-09)
      A 54-year-old male with metastatic melanoma, including a presumed brain metastasis underwent elective surgery when there was sudden onset of extensive bleeding upon resection. An emergent cerebral angiogram revealed a fusiform left posterior cerebral artery aneurysm. Malignant melanoma commonly metastasizes to the brain and has shown to assume a wide variety of appearances with involvement of almost any intracranial structures. The unexpected intraoperative finding required immediate action and strategic rethinking. The patient successfully underwent vessel sacrifice by means of coil embolization.
    • Trapped Embolic Protection Device: A Salvage Technique

      Kuhn, Anna L.; Puri, Ajit S.; de Macedo Rodrigues, Katyucia; Massari, Francesco; Singh, Jasmeet (2020-07-16)
      After carotid artery stenting, retrieval of the embolic protection device can sometimes be difficult due to incomplete stent expansion, stent fracture, vasospasm, and vessel tortuosity. In this technical report, we describe a novel rescue technique used in a patient with diffuse calcific atherosclerosis of the left common and proximal left internal carotid arteries who underwent left internal carotid artery stenting with cerebral protection and in whom, due to an under-expanded proximal carotid stent strut in relation to a densely calcified plaque, we were initially unable to advance the retrieval device.
    • Use of self-expanding stents for better intracranial flow diverter wall apposition

      Kuhn, Anna L.; Wakhloo, Ajay K.; Gounis, Matthew J.; Kan, Peter; de Macedo Rodrigues, Katyucia; Lozano, Juan Diego; Marosfoi, Miklos G.; Perras, Mary; Brooks, Christopher; Howk, Mary; et al. (2017-04-01)
      Background Flow diverter (FD) malapposition is associated with stroke-related complications. We document the use of self-expanding nitinol stents to remove/reduce the ledge of a FD deployed for aneurysm treatment. Methods We identified five patients who were treated with the Pipeline embolization device (PED) in conjunction with a Neuroform EZ stent for inadequate wall apposition of the ends of the FD at our institution between May 2014 and July 2015. Among other parameters, angiographic results, cone-beam computed tomography assessment of wall apposition and patient clinical outcome were evaluated. Results Incomplete device end apposition was seen in three cases, and precarious positioning of the distal end of the PED over the aneurysm neck was seen in two cases. In all five cases, successful treatment with good wall apposition and proper pinning of the PED distal edge was achieved using an additional Neuroform EZ stent. Appropriate aneurysm neck coverage and flow stagnation was seen in all cases. The combination of high radial outward force and open-cell design permits the Neuroform EZ stent to jail the malappositioned edges of the FD while maintaining good vessel-wall apposition itself and prevent migration of the PED. Short-term follow-up angiography showed device patency and complete aneurysm obliteration in all cases. Conclusions Preliminary results of this small case series suggest that the Neuroform EZ stent allows for effective treatment of FD malapposition in selected patients amenable for this endovascular approach. Long-term and larger cohort studies are needed to validate these results.
    • Use of the Pipeline embolization device for recurrent and residual cerebral aneurysms: a safety and efficacy analysis with short-term follow-up

      Kuhn, Anna L.; de Macedo Rodrigues, Katyucia; Lozano, Juan Diego; Rex, David E.; Massari, Francesco; Tamura, Takamitsu; Howk, Mary; Brooks, Christopher; L'Heureux, Jenna; Gounis, Matthew J.; et al. (2017-12-01)
      OBJECTIVE: Evaluation of the safety and efficacy of the Pipeline embolization device (PED) when used as second-line treatment for recurrent or residual, pretreated ruptured and unruptured intracranial aneurysms (IAs). METHODS: Retrospective review of our database to include all patients who were treated with a PED for recurrent or residual IAs following surgical clipping or coiling. We evaluated neurological outcome and angiograms at discharge, 6- and 12-months' follow-up and assessed intimal hyperplasia at follow-up. RESULTS: Twenty-four patients met our inclusion criteria. Most IAs were located in the anterior circulation (n=21). No change of preprocedure modified Rankin Scale score was seen at discharge or at any scheduled follow-up. Complete or near-complete aneurysm occlusion on 6- and 12-month angiograms was seen in 94.4% (17/18 cases) and 93.3% (14/15 cases), respectively. Complete or near-complete occlusion was seen in 100% of previously ruptured and 85.7% (6/7 cases) and 83.3% (5/6 cases) of previously unruptured cases at the 6- and 12-months' follow-up, respectively. One case of moderate intimal hyperplasia was observed at 6 months and decreased to mild at the 12-months' follow-up. No difference in device performance was observed among pretreated unruptured or ruptured IAs. CONCLUSIONS: Treatment of recurrent or residual IAs with a PED after previous coiling or clipping is feasible and safe. There is no difference in device performance between ruptured or unruptured IAs.