Browsing by keyword "Silver Sulfadiazine"
Now showing items 1-3 of 3
-
A comparison of two antimicrobial-impregnated central venous catheters. Catheter Study GroupBACKGROUND: The use of central venous catheters impregnated with either minocycline and rifampin or chlorhexidine and silver sulfadiazine reduces the rates of catheter colonization and catheter-related bloodstream infection as compared with the use of unimpregnated catheters. We compared the rates of catheter colonization and catheter-related bloodstream infection associated with these two kinds of antiinfective catheters. METHODS: We conducted a prospective, randomized clinical trial in 12 university-affiliated hospitals. High-risk adult patients in whom central venous catheters were expected to remain in place for three or more days were randomly assigned to undergo insertion of polyurethane, triple-lumen catheters impregnated with either minocycline and rifampin (on both the luminal and external surfaces) or chlorhexidine and silver sulfadiazine (on only the external surface). After their removal, the tips and subcutaneous segments of the catheters were cultured by both the roll-plate and the sonication methods. Peripheral-blood cultures were obtained if clinically indicated. RESULTS: Of 865 catheters inserted, 738 (85 percent) produced culture results that could be evaluated. The clinical characteristics of the patients and the risk factors for infection were similar in the two groups. Catheters impregnated with minocycline and rifampin were 1/3 as likely to be colonized as catheters impregnated with chlorhexidine and silver sulfadiazine (28 of 356 catheters [7.9 percent] vs. 87 of 382 [22.8 percent], P CONCLUSIONS: The use of central venous catheters impregnated with minocycline and rifampin is associated with a lower rate of infection than the use of catheters impregnated with chlorhexidine and silver sulfadiazine.
-
Anti-infective external coating of central venous catheters: a randomized, noninferiority trial comparing 5-fluorouracil with chlorhexidine/silver sulfadiazine in preventing catheter colonizationOBJECTIVE: The antimetabolite drug, 5-fluorouracil, inhibits microbial growth. Coating of central venous catheters with 5-fluorouracil may reduce the risk of catheter infection. Our objective was to compare the safety and efficacy of central venous catheters externally coated with 5-fluorouracil with those coated with chlorhexidine and silver sulfadiazine. DESIGN: Prospective, single-blind, randomized, active-controlled, multicentered, noninferiority trial. SETTING: Twenty-five US medical center intensive care units. PATIENTS: A total of 960 adult patients requiring central venous catheterization for up to 28 days. INTERVENTIONS: Patients were randomized to receive a central venous catheter externally coated with either 5-fluorouracil (n = 480) or chlorhexidine and silver sulfadiazine (n = 480). MEASUREMENTS AND MAIN RESULTS: The primary antimicrobial outcome was a dichotomous measure (/= 15 colony-forming units) for catheter colonization determined by the roll plate method. Secondary antimicrobial outcomes included local site infection and catheter-related bloodstream infection. Central venous catheters coated with 5-fluorouracil were noninferior to chlorhexidine and silver sulfadiazine coated central venous catheters with respect to the incidence of catheter colonization (2.9% vs. 5.3%, respectively). Local site infection occurred in 1.4% of the 5-fluorouracil group and 0.9% of the chlorhexidine and silver sulfadiazine group. No episode of catheter-related bloodstream infection occurred in the 5-fluorouracil group, whereas two episodes were noted in the chlorhexidine and silver sulfadiazine group. Only Gram-positive organisms were cultured from 5-fluorouracil catheters, whereas Gram-positive bacteria, Gram-negative bacteria, and Candida were cultured from the chlorhexidine and silver sulfadiazine central venous catheters. Adverse events were comparable between the two central venous catheter coatings. CONCLUSIONS: Our results suggest that central venous catheters externally coated with 5-fluorouracil are a safe and effective alternative to catheters externally coated with chlorhexidine and silver sulfadiazine when used in critically ill patients.
-
Influence of triple-lumen central venous catheters coated with chlorhexidine and silver sulfadiazine on the incidence of catheter-related bacteremiaOBJECTIVE: To evaluate the efficacy of triple-lumen central venous catheters coated with a combination product of chlorhexidine and silver sulfadiazine (CSS) in reducing the incidence of local catheter infection and catheter-related bacteremia. DESIGN: Randomized, controlled trial. SETTING: The surgical intensive care units in a university hospital. PATIENTS: All patients who needed central venous catheterization were randomized to receive either an uncoated triple-lumen catheter (n = 157) or a catheter coated with CSS (n = 151). MAIN OUTCOME MEASURE: Catheters were removed when no longer needed or suspected as a cause of infection. The tip and a 5-cm segment of the intradermal portion of the catheter were cultured semiquantitatively. Blood cultures were obtained when clinically indicated. The remaining segment of catheters coated with CSS were cut and incubated on an agar plate with strains of Staphylococcus aureus and Enterococcus. Zone of inhibition was determined 24 hours later. Data were analyzed by survival and logistic multivariate regression methods. RESULTS: Catheters coated with CSS were effective in reducing the rate of significant bacterial growth on either the tip or intradermal segment (40%) compared with control catheters (52%; P = .04). However, there was no difference in the incidence of catheter-related bacteremia (3.8% [uncoated] vs 3.3% [coated]; P = .81). In vitro activity of catheters with CSS against S aureus was evident up to 25 days but activity against Enterococcus dissipated more quickly over time and was absent by day 4. The most common colonizing organisms were coagulase-negative staphylococcus and enterococcus. Variables that were associated with a significant amount of growth on the tip or intradermal segment were a duration of catheterization of longer than 7 days, jugular insertion site, and the absence of a CSS coating. The use of a guidewire when the catheter was removed was associated with a lower risk of significant bacterial growth. CONCLUSIONS: The use of CSS reduces the incidence of significant bacterial growth on either the tip or intradermal segments of coated triple-lumen catheters but has no effect on the incidence of catheter-related bacteremia. In this patient population, catheters coated with CSS provide no additional benefit over uncoated catheters.