• Acute thrombus formation on phosphorilcholine surface modified flow diverters

      Marosfoi, Miklos G.; Clarencon, Frederic; Langan, Erin T.; King, Robert M.; Brooks, Olivia W.; Tamura, Takamitsu; Wainwright, John M.; Gounis, Matthew J.; Vedantham, Srinivasan; Puri, Ajit S. (2017-07-08)
      PURPOSE: Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS: Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. RESULTS: Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p < 0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). CONCLUSION: In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device.
    • Early postmarket results with PulseRider for treatment of wide-necked intracranial aneurysms: a multicenter experience

      Srinivasan, Visish M.; Puri, Ajit S.; Kan, Peter (2019-11-08)
      OBJECTIVE: Traditionally, stent-assisted coiling and balloon remodeling have been the primary endovascular treatments for wide-necked intracranial aneurysms with complex morphologies. PulseRider is an aneurysm neck reconstruction device that provides parent vessel protection for aneurysm coiling. The objective of this study was to report early postmarket results with the PulseRider device. METHODS: This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed ( > 30 days after the procedure) complications. RESULTS: A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2. CONCLUSIONS: PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist's armamentarium, especially with regard to its off-label use.