• Login
    Search 
    •   Home
    • Search
    •   Home
    • Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of eScholarship@UMassChanCommunitiesPublication DateAuthorsUMass Chan AffiliationsTitlesDocument TypesKeywords

    My Account

    LoginRegister

    Filter by Category

    Date Issued2017 (1)2013 (1)Author
    Barry, Carol (2)
    De Jesus Vega, Marisel (1)Orbey, Nese (1)Orby, Nese (1)Wakim, Joseph (1)Document TypePoster Abstract (2)KeywordBiomedical Devices and Instrumentation (2)Translational Medical Research (2)Biological Factors (1)Biomaterials (1)Biomechanics and Biotransport (1)View More

    Help

    AboutSubmission GuidelinesData Deposit PolicySearchingTerms of UseWebsite Migration FAQ

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors
     

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    • Publications
    • Profiles

    Now showing items 1-2 of 2

    • List view
    • Grid view
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    • 2CSV
    • 2RefMan
    • 2EndNote
    • 2BibTex
    • Selective Export
    • Select All
    • Help
    Thumbnail

    Optimizing Microfluidic Design for Cell Separation

    Wakim, Joseph; De Jesus Vega, Marisel; Orbey, Nese; Barry, Carol (2017-05-16)
    To evaluate the performance of various designs of crossflow filtration microfluidic devices, blood flow was modeled using computational fluid dynamics software (COMSOL Multiphysics). Velocity profiles were generated and used to analyze four critical design parameters: pillar size, pillar shape, gap size, and wall length. These parameters were optimized to yield greatest flow from an unfiltered main channel into two filtered side channels of the device, thereby maximizing filtration capacity. Devices containing pillars of 10 µm diameter yielded a significantly greater filtration capacity than devices with pillars of 20 µm diameter. Flow patterns from the main channel to the side channels were not significantly affected when circular, octagonal, and hexagonal pillars were compared; however, use of triangular and square pillars caused a reduction in side channel flow rates. Side channel velocities consistently improved as gap sizes were increased from 3.0 µm to 8.0 µm; however, 3.5 µm gaps were included in the final design for the purpose of separating red and white blood cells. Backflow prevention walls were placed at bends in the device and were systematically lengthened until all backflow was eliminated. Following optimization of the microfluidic device, two prototypes were prepared: a polydimethylsiloxane (PDMS) device with glass backing and a silicon device with PDMS backing. The filtration capacity of these devices were tested using polystyrene microspheres with sizes corresponding to those of red and white blood cells. In both prototypes, between 73 and 75% of small microspheres were consistently filtered into the side channels. Silicon-PDMS devices demonstrated better retention of large microspheres in the main channel and less microsphere agglomeration than did PDMS-glass devices. The benefits of silicon-PDMS devices, however, came at the cost of a difficult fabrication process.
    Thumbnail

    Use of Novel Microfluidic Devices to Detect Biomarkers in Blood

    Orby, Nese; Barry, Carol (2013-05-08)
    Blood analysis is highly important in both medical and scientific fields. Traditionally, blood analysis requires a vial of blood and several processing steps resulting in a time consuming and difficult process. The aim of this research is to find a portable and inexpensive device to carry out fast blood cells separation, count and analysis. Previous work show the capability to analyze and separate blood cells using microfluidic devices resulting in less sample volume and shorter analysis time. Most microfluidic devices share similar fabrication process and materials (soft lithography process in polydimethylsiloxane (PDMS)). ELISA (enzyme-linked immunosorbent assay) is the most common method that these devices use. Microfluidic devices have antibodies microarrays and these antibodies will attract/bind to specific viruses or cells enabling the detection of specific diseases. Sometimes allergies can’t be diagnosed by the common skin prick test and a blood test is needed. The available blood allergy test is more expensive and takes more days to obtain the results than the skin test. Microfluidic devices using ELISA can measure the blood level of immunoglobulin E (IgE). The IgE are antibodies that the body may make in response to certain allergens. Therefore microfluidic devices can be use to make blood allergy tests in a less expensive and time consuming manner than currently allergy blood tests. Psychological disorders such as bipolar disorder, major depression disorder, posttraumatic stress disorder and schizophrenia, are commonly diagnosed by the physician’s judgment based on the patient description of his symptoms. Sometimes it is difficult to get an accurate diagnosis or determine the severity of the patient’s condition based on this. An accurate genetic blood test it can guarantee that the patients are getting the right medication in the proper dosage amounts and that the patients will search the help they need because mental disorders would be viewed the same as any other medical condition. Researchers identified some genes and proteins that are candidate biomarkers for these disorders. However, these are only suggested biomarkers and the selectivity and sensitivity of these need further testing and investigation in order to be able to obtain accurate diagnosis of mental disorders using blood tests.
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Lamar Soutter Library, UMass Chan Medical School | 55 Lake Avenue North | Worcester, MA 01655 USA
    Quick Guide | escholarship@umassmed.edu
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.