• Login
    Search 
    •   Home
    • Search
    •   Home
    • Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of eScholarship@UMassChanCommunitiesPublication DateAuthorsUMass Chan AffiliationsTitlesDocument TypesKeywords

    My Account

    LoginRegister

    Filter by Category

    Date Issued2010 - 2014 (2)2001 - 2009 (2)AuthorEaton, Roger B. (4)
    Zytkovicz, Thomas H. (4)
    Comeau, Anne Marie (2)Fitzgerald, Eileen F. (2)Grady, George F. (2)View MoreUMass Chan AffiliationDepartment of Pediatrics (4)New England Newborn Screening Program (4)Document TypeJournal Article (3)Book Chapter (1)KeywordPediatrics (4)Medical Genetics (3)Genetics and Genomics (2)Humans (2)Infant, Newborn (2)View MoreJournalClinical biochemistry (1)Clinical chemistry (1)Pediatrics (1)

    Help

    AboutSubmission GuidelinesData Deposit PolicySearchingTerms of UseWebsite Migration FAQ

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors
     

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    • Publications
    • Profiles

    Now showing items 1-4 of 4

    • List view
    • Grid view
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    • 4CSV
    • 4RefMan
    • 4EndNote
    • 4BibTex
    • Selective Export
    • Select All
    • Help
    Thumbnail

    Newborn Screening for Glutaric Aciduria-II: The New England Experience

    Sahai, Inderneel; Garganta, C. L.; Bailey, J.; James, P.; Levy, H. L.; Martin, M.; Neilan, E.; Phornphutkul, C.; Sweetser, D. A.; Zytkovicz, Thomas H.; et al. (2014-01-01)
    Newborn screening (NBS) using tandem mass spectrometry (MS/MS) permits detection of neonates with Glutaric Aciduria-Type II (GA-II). We report follow-up of positive GA-II screens by the New England Newborn Screening Program. METHODS: 1.5 million infants were screened for GA-II (Feb 1999-Dec 2012). Specialist consult was suggested for infants with two or more acylcarnitine elevations suggestive of GA-II. RESULTS: 82 neonates screened positive for GA-II, 21 weighing > 1.5 kg and 61 weighing < /= 1.5 kg. Seven (one weighing < 1.5 kg), were confirmed with GA-II. Four of these had the severe form (died < 1 week). The other three have a milder form and were identified because of newborn screening. Two (ages > 5 years) have a G-Tube in place, had multiple hospitalizations and are slightly hypotonic. The third infant remains asymptomatic (9 months old). Two GA-II carriers were also identified. The remaining positive screens were classified as false positives (FP). Six infants ( > 1.5 kg) classified as FP had limited diagnostic work-up. Characteristics and outcomes of all specimens and neonates with a positive screen were reviewed, and marker profiles of the cases and FP were compared to identify characteristic profiles. CONCLUSION: In addition to the severe form of GA-II, milder forms of GA-II and some GA-II carriers are identified by newborn screening. Some positive screens classified as FP may be affected with a milder form of the disorder. Characteristic GA-II profiles, quantified as GA-II indexes, may be utilized to predict probability of disorder and direct urgency of intervention for positive screens.
    Thumbnail

    Newborn screening for hepatorenal tyrosinemia-I by tandem mass spectrometry using pooled samples: a four-year summary by the New England newborn screening program

    Zytkovicz, Thomas H.; Sahai, Inderneel; Rush, Amii; Odewale, Adedoyin; Johnson, Donna M.; Fitzgerald, Eileen F.; Britton, Deborah; Eaton, Roger B. (2013-05-01)
    OBJECTIVE: The objective of this study is to develop an isotope dilution liquid chromatography tandem mass spectrometry assay to screen for hepatorenal tyrosinemia (HT) from newborn filter paper samples using pooled extracts to increase high throughput screening. DESIGN AND METHODS: Succinylacetone (SUAC), the marker for HT, was extracted from dried blood spots with the formation of the hydrazone derivative of SUAC; up to eight sample extracts were pooled and the SUAC-derivative was analyzed by mass spectrometry methods with an injection-to-injection time of one minute. If any pooled sample extract screened positive, then the samples comprising the pooled sample were assayed individually. RESULTS: Two newborn infants were identified with high levels of SUAC (7 and 23muM) and later confirmed to have HT. Three older children whose initial filter paper samples were taken at 195days to 614days of age with elevated SUAC (range 4.9-5muM) were identified; one of the three had clinical signs of HT and was placed on treatment (diagnosis of the other two are unavailable). CONCLUSION: MS/MS analysis of pooled dried blood sample extracts permits sensitive, reduced instrumental analytical time and increase high throughput screening for HT. Elsevier Inc. All rights reserved.
    Thumbnail

    Spectrum of medium-chain acyl-CoA dehydrogenase deficiency detected by newborn screening

    Hsu, Ho-Wen; Zytkovicz, Thomas H.; Comeau, Anne Marie; Strauss, Arnold W.; Marsden, Deborah; Shih, Vivian E.; Grady, George F.; Eaton, Roger B. (2008-05-03)
    OBJECTIVE: Our goal was to describe the clinical spectrum of medium-chain acyl-CoA dehydrogenase deficiency detected by routine newborn screening and assess factors associated with elevations of octanoylcarnitine in newborns and characteristics associated with adverse clinical consequences of medium-chain acyl-CoA dehydrogenase deficiency. METHODS: The first 47 medium-chain acyl-CoA dehydrogenase deficiency cases detected by the New England Newborn Screening Program were classified according to initial and follow-up octanoylcarnitine values, octanoylcarnitine-decanoylcarnitine ratios, medium-chain acyl-CoA dehydrogenase genotype, follow-up biochemical parameters, and feeding by breast milk or formula. RESULTS: All 20 patients who were homozygous for 985A-->G had high initial octanoylcarnitine values (7.0-36.8 microM) and octanoylcarnitine-decanoylcarnitine ratios (7.0-14.5), whereas the 27 patients with 0 to 1 copy of 985A-->G exhibited a wide range of octanoylcarnitine values (0.5-28.6 microM) and octanoylcarnitine-decanoylcarnitine ratios (0.8-12.7). Initial newborn octanoylcarnitine values decreased by days 5 to 8, but the octanoylcarnitine-decanoylcarnitine ratio generally remained stable. Among 985A-->G homozygotes, breastfed newborns had higher initial octanoylcarnitine values than newborns who received formula. Adverse events occurred in 5 children, 4 985A-->G homozygotes and 1 compound heterozygote with a very high initial octanoylcarnitine: 2 survived severe neonatal hypoglycemia, 1 survived a severe hypoglycemic episode at 15 months of age, and 2 died as a result of medium-chain acyl-CoA dehydrogenase deficiency at ages 11 and 33 months. CONCLUSION: Newborn screening for medium-chain acyl-CoA dehydrogenase deficiency has detected cases with a wide range of genotypes and biochemical abnormalities. Although most children do well, adverse outcomes have not been entirely avoided. Assessment of potential risk and determination of appropriate treatment remain a challenge.
    Thumbnail

    Tandem mass spectrometric analysis for amino, organic, and fatty acid disorders in newborn dried blood spots: a two-year summary from the New England Newborn Screening Program

    Zytkovicz, Thomas H.; Fitzgerald, Eileen F.; Marsden, Deborah; Larson, Cecilia A.; Shih, Vivian E.; Johnson, Donna M.; Strauss, Arnold W.; Comeau, Anne Marie; Eaton, Roger B.; Grady, George F. (2001-10-24)
    BACKGROUND: Tandem mass spectrometry (MS/MS) is rapidly being adopted by newborn screening programs to screen dried blood spots for >20 markers of disease in a single assay. Limited information is available for setting the marker cutoffs and for the resulting positive predictive values. METHODS: We screened >160 000 newborns by MS/MS. The markers were extracted from blood spots into a methanol solution with deuterium-labeled internal standards and then were derivatized before analysis by MS/MS. Multiple reaction monitoring of each sample for the markers of interest was accomplished in approximately 1.9 min. Cutoffs for each marker were set at 6-13 SD above the population mean. RESULTS: We identified 22 babies with amino acid disorders (7 phenylketonuria, 11 hyperphenylalaninemia, 1 maple syrup urine disease, 1 hypermethioninemia, 1 arginosuccinate lyase deficiency, and 1 argininemia) and 20 infants with fatty and organic acid disorders (10 medium-chain acyl-CoA dehydrogenase deficiencies, 5 presumptive short-chain acyl-CoA dehydrogenase deficiencies, 2 propionic acidemias, 1 carnitine palmitoyltransferase II deficiency, 1 methylcrotonyl-CoA carboxylase deficiency, and 1 presumptive very-long chain acyl-CoA dehydrogenase deficiency). Approximately 0.3% of all newborns screened were flagged for either amino acid or acylcarnitine markers; approximately one-half of all the flagged infants were from the 5% of newborns who required neonatal intensive care or had birth weights <1500 g. CONCLUSIONS: In screening for 23 metabolic disorders by MS>/MS, an mean positive predictive value of 8% can be achieved when using cutoffs for individual markers determined empirically on newborns.
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Lamar Soutter Library, UMass Chan Medical School | 55 Lake Avenue North | Worcester, MA 01655 USA
    Quick Guide | escholarship@umassmed.edu
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.