Reproducibility of Neuroretinal Rim Measurements Obtained from High-Density Spectral Domain Optical Coherence Tomography Volume Scans

Kim, Janice
Men, Clara J
Ratanawongphaibul, Kitiya
Papadogeorgou, Georgia
Tsikata, Edem
Ben-David, Geulah S
Antar, Hussein
Poon, Linda Yi-Chieh
Freeman, Madeline
Park, Elli A
... show 3 more
Embargo Expiration Date
Abstract

Purpose: To compare the reproducibility of two-dimensional (2D) peripapillary retinal nerve fiber layer (RNFL) thickness and three-dimensional (3D) neuroretinal rim measurements using spectral domain optical coherence tomography (SDOCT) in normal and glaucoma subjects.

Methods: One eye per subject for 27 normal and 40 glaucoma subjects underwent repeat SDOCT RNFL thickness scans and optic nerve volume scans on the same day. From the volume scan, custom software calculated five neuroretinal rim parameters: 3D minimum distance band (MDB) thickness, 3D MDB area, 3D rim volume, 2D rim area, and 2D rim thickness. Within-subject variance (Sw), coefficient of variation (CV), and intraclass correlation coefficient (ICC) were analyzed.

Results: MDB thickness and RNFL thickness have similar reproducibility among normal and glaucoma subjects (eg, global MDB thickness CVs of 2.4% and 3.6%, and global RNFL thickness CVs of 1.3% and 2.2%; P > 0.05 for both comparisons). Reproducibility of MDB thickness was lower in glaucoma patients for the superior and inferior quadrants compared to normal subjects (CVs of 9.6% versus 3.4% and 6.9% versus 2.7%; P < 0.05, respectively). There were no statistically significant differences between both groups for RNFL thickness in the four quadrants. For both patient groups and for all regions, MDB thickness had the lowest CVs among all five neuroretinal rim parameters (eg, global MDB thickness CVs of 2.4% and 3.6% versus 3.0% and 18.9% for the other four neuroretinal rim parameters).

Conclusion: Global MDB and global RNFL thickness are similarly reproducible among normal and glaucoma subjects, though MDB thickness for the superior and inferior quadrants is less reproducible among glaucoma subjects.

Source

Kim J, Men CJ, Ratanawongphaibul K, Papadogeorgou G, Tsikata E, Ben-David GS, Antar H, Poon LY, Freeman M, Park EA, Guzman Aparicio MA, de Boer JF, Chen TC. Reproducibility of Neuroretinal Rim Measurements Obtained from High-Density Spectral Domain Optical Coherence Tomography Volume Scans. Clin Ophthalmol. 2022 Aug 13;16:2595-2608. doi: 10.2147/OPTH.S369807. PMID: 35992568; PMCID: PMC9384967.

Year of Medical School at Time of Visit
Sponsors
Dates of Travel
DOI
10.2147/OPTH.S369807
PubMed ID
35992568
Other Identifiers
Notes
Funding and Acknowledgements
Corresponding Author
Related Resources
Related Resources
Repository Citation
Rights
© 2022 Kim et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php)