Observer studies of image quality of denoising reduced-count cardiac single photon emission computed tomography myocardial perfusion imaging by three-dimensional Gaussian post-reconstruction filtering and deep learning

Pretorius, P. Hendrik
Liu, Junchi
Kalluri, Kesava S
Jiang, Yulei
Leppo, Jeffery A
Dahlberg, Seth T
Kikut, Janusz
Parker, Matthew W
Keating, Friederike K
Licho, Robert
... show 6 more
Embargo Expiration Date
Abstract

Background: The aim of this research was to asses perfusion-defect detection-accuracy by human observers as a function of reduced-counts for 3D Gaussian post-reconstruction filtering vs deep learning (DL) denoising to determine if there was improved performance with DL.

Methods: SPECT projection data of 156 normally interpreted patients were used for these studies. Half were altered to include hybrid perfusion defects with defect presence and location known. Ordered-subset expectation-maximization (OSEM) reconstruction was employed with the optional correction of attenuation (AC) and scatter (SC) in addition to distance-dependent resolution (RC). Count levels varied from full-counts (100%) to 6.25% of full-counts. The denoising strategies were previously optimized for defect detection using total perfusion deficit (TPD). Four medical physicist (PhD) and six physician (MD) observers rated the slices using a graphical user interface. Observer ratings were analyzed using the LABMRMC multi-reader, multi-case receiver-operating-characteristic (ROC) software to calculate and compare statistically the area-under-the-ROC-curves (AUCs).

Results: For the same count-level no statistically significant increase in AUCs for DL over Gaussian denoising was determined when counts were reduced to either the 25% or 12.5% of full-counts. The average AUC for full-count OSEM with solely RC and Gaussian filtering was lower than for the strategies with AC and SC, except for a reduction to 6.25% of full-counts, thus verifying the utility of employing AC and SC with RC.

Conclusion: We did not find any indication that at the dose levels investigated and with the DL network employed, that DL denoising was superior in AUC to optimized 3D post-reconstruction Gaussian filtering.

Source

Pretorius PH, Liu J, Kalluri KS, Jiang Y, Leppo JA, Dahlberg ST, Kikut J, Parker MW, Keating FK, Licho R, Auer B, Lindsay C, Konik A, Yang Y, Wernick MN, King MA. Observer studies of image quality of denoising reduced-count cardiac single photon emission computed tomography myocardial perfusion imaging by three-dimensional Gaussian post-reconstruction filtering and deep learning. J Nucl Cardiol. 2023 May 23. doi: 10.1007/s12350-023-03295-3. Epub ahead of print. PMID: 37221409.

Year of Medical School at Time of Visit
Sponsors
Dates of Travel
DOI
10.1007/s12350-023-03295-3
PubMed ID
37221409
Other Identifiers
Notes
Funding and Acknowledgements
Corresponding Author
Related Resources
Related Resources
Repository Citation
Rights
© 2023. The Author(s) under exclusive licence to American Society of Nuclear Cardiology.
Distribution License