Publication

Flow diverter stents for unruptured saccular anterior circulation perforating artery aneurysms: safety, efficacy, and short-term follow-up

Kuhn, Anna L.
Hou, Samuel Y.
Perras, Mary
Brooks, Christopher
Gounis, Matthew J
Wakhloo, Ajay K.
Puri, Ajit S
Citations
Altmetric:
Student Authors
Faculty Advisor
Academic Program
UMass Chan Affiliations
Document Type
Journal Article
Publication Date
2014-07-21
Subject Area
Embargo Expiration Date
Abstract

BACKGROUND: Anterior circulation perforating artery aneurysms including anterior choroidal artery and lenticulostriate artery aneurysms are rare. Injury to these vessels can lead to severe debilitating symptoms.

OBJECTIVE: To present a new approach to treatment using flow diversion technology.

METHODS: Patients treated with a Pipeline embolization device (PED) for perforator artery aneurysms at our institution between June 2012 and May 2013 were identified and included in our retrospective analysis. We evaluated patient vascular risk factors; family history of aneurysms; aneurysm characteristics; National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) on admission; and angiography follow-up and patient clinical outcome at discharge, 6 months, and 1 year.

RESULTS: We included four patients with a mean age of 59.8 years. Two patients had a positive family history of aneurysms. Patient vascular risk factors included smoking, dyslipidemia, and hypertension. All patients presented with a NIHSS and mRS of 0 on admission. Aneurysms were located at the anterior choroidal (n=2) or lenticulostriate artery (n=2) and were treated with a single PED. No periprocedural or postprocedural complications occurred. The patients were discharged with no change in NHISS or mRS score. Six-month and 1-year follow-up angiography showed complete aneurysm occlusion. Mild intimal hyperplasia was seen in 2 cases at 6 months, but was resolved at the 1-year follow-up. No re-treatment was necessary. NIHSS and mRS remained 0 at follow-up time points.

CONCLUSIONS: Our preliminary results show that flow diversion technology is an effective and safe therapy for complex, hard-to-treat aneurysms in perforating arteries. Larger studies with long-term follow-up are needed to validate our promising results.

Source

J Neurointerv Surg. 2014 Jul 21. pii: neurintsurg-2014-011237. doi: 10.1136/neurintsurg-2014-011237. Link to article on publisher's site.

Year of Medical School at Time of Visit
Sponsors
Dates of Travel
DOI
10.1136/neurintsurg-2014-011237
PubMed ID
25051964
Other Identifiers
Notes
Funding and Acknowledgements
Corresponding Author
Related Resources
Related Resources
Repository Citation
Rights
Distribution License