Publication

Reproducibility and reliability of middle cerebral artery occlusion using a silicone-coated suture (Koizumi) in rats

Takano, Kentaro
Tatlisumak, Turgut
Bergmann, Andreas G.
Gibson, Daniel G. III
Fisher, Marc
Embargo Expiration Date
Abstract

The best technical approach to rat middle cerebral artery occlusion (MCAO) using a nylon-monofilament suture remains unsettled, regarding the usefulness of coated or uncoated sutures. Three investigators with different degrees of experience: A, well skilled; B, 2 years of experience; C, a novice with 6 months of experience, each subjected 10 Sprague-Dawley rats to permanent MCAO using low-viscosity silicone-coated sutures with a mean diameter 0.468+/-0.013 mm (mean+/-S.D.) at the tip and 0.361+/-0.013 mm in the body. Post-mortem corrected infarct size 24 h after MCAO was similar among the three investigators: A, 204.7+/-33.2 mm3; B, 212.6+/-42.8, and C, 195.9+/-44.4. The coefficient of variation was 16.2% to 22.7%, and 19.4% for the three investigators. This study suggests that experimental stroke with silicone-coated sutures (Koizumi's method) provides good reproducibility and reliability, among investigators of varying experience.

Source

J Neurol Sci. 1997 Dec 9;153(1):8-11.

Year of Medical School at Time of Visit
Sponsors
Dates of Travel
DOI
PubMed ID
9455971
Other Identifiers
Notes
Funding and Acknowledgements
Corresponding Author
Related Resources
Related Resources
Repository Citation
Rights
Distribution License