Publication

Adult intestinal intussusception: can abdominal MDCT distinguish an intussusception caused by a lead point

Tresoldi, Silvia
Kim, Young H
Blake, Michael A.
Harisinghani, Mukesh G.
Hahn, Peter F.
Baker, Stephen P.
Mueller, Peter R.
Kandarpa, Krishna
Embargo Expiration Date
Abstract

BACKGROUND : Aim of our study was to assess the ability of computed tomography to distinguish between an intussusception with a lead-point from one without it.

METHODS : Approval was granted by the Institutional Review Board. Ninety-three consecutive patients diagnosed with an intussusception on abdominal CT were classified with or without lead-point by surgery, clinical or radiological follow-up. Two radiologists blinded to the classification independently reviewed the CT images for predefined predictive variables.

RESULTS : Non-lead-point intussusception was shorter in length (mean 4.9 vs. 11.1 cm for Reader 1 (R1); mean 4.0 vs. 8.9 cm for Reader 2 (R2), respectively, P < 0.001), smaller in axial diameter (mean 3.0 vs. 4.8 cm for R1; mean 2.8 vs. 4.4 cm for R2, P < 0.001, respectively), less likely associated with obstruction (P = 0.002 R1; P = 0.039 R2) and infiltration (P < 0.001 for R1, P = 0.003 R2) than lead-point intussusception.

CONCLUSIONS : Abdominal CT is helpful in distinguishing between an intussusception with a lead-point from one without a lead-point. Length, axial diameter, and their product, as well as obstruction and infiltration, all suggest the presence of a lead-point. Analysis of CT findings can reduce unnecessary imaging follow-up or operation.

Source

Abdom Imaging. 2007 Oct 9;. Link to article on publisher's site

Year of Medical School at Time of Visit
Sponsors
Dates of Travel
DOI
10.1007/s00261-007-9328-8
PubMed ID
17924160
Other Identifiers
Notes
Funding and Acknowledgements
Corresponding Author
Related Resources
Related Resources
Repository Citation
Rights
Distribution License