Loading...
Thumbnail Image
Publication

Do high-frequency air-bone gaps persist after ossiculoplasty?

Polanik, Marc D
Trakimas, Danielle R
Castillo-Bustamante, Melissa
Cheng, Jeffrey T
Kozin, Elliott D
Remenschneider, Aaron K
Embargo Expiration Date
Abstract

Objectives: Conventional reporting of postoperative hearing outcomes utilizes a pure-tone averaged air-bone gap (ABG) that is biased toward low frequencies. Consequently, a high-frequency ABG after otologic surgery may go unnoticed. In this study, we evaluate changes in low- and high-frequency ABG following ossiculoplasty.

Study design: Retrospective review.

Subjects and setting: Consecutive series of patients who underwent ossiculoplasty at a single tertiary care center. Patients with pre- and postoperative audiograms were included.

Methods: Low-frequency ABG was calculated as the mean ABG at 250, 500, and 1000 Hz. High-frequency ABG was calculated at 4 kHz. Pre- and postoperative ABGs were compared.

Results: Thirty-seven consecutive patients were included. Mean age at surgery was 38 years (range, 7-77 years). Reconstruction materials included: cartilage (N = 4), hydroxyapatite cement (N = 5), and partial or total ossicular replacement prostheses (N = 20 and N = 8, respectively). Postoperatively, the mean low-frequency ABG improved by 11.9 ± 15.1 dB (P < .0001) and the mean high-frequency ABG improved by 5.9 ± 16.0 dB (P = .030). Low-frequency ABG closure was significantly larger than high-frequency ABG closure (P = .007). Mean postoperative persistent high-frequency ABG was 22.0 ± 13.8 dB.

Conclusion: In this series, ossiculoplasty improved ABG across all frequencies, but greater improvements were observed at low frequencies when compared to high frequency. Current reporting standards may not identify persistent high-frequency ABG. Additional study of the mechanisms of high-frequency sound conduction in reconstructed middle ears is needed to improve high-frequency hearing outcomes in ossiculoplasty.

Level of evidence: Level 4.

Source

Polanik MD, Trakimas DR, Castillo-Bustamante M, Cheng JT, Kozin ED, Remenschneider AK. Do high-frequency air-bone gaps persist after ossiculoplasty? Laryngoscope Investig Otolaryngol. 2020 Jun 26;5(4):734-742. doi: 10.1002/lio2.418. PMID: 32864446; PMCID: PMC7444777.

Year of Medical School at Time of Visit
Sponsors
Dates of Travel
DOI
10.1002/lio2.418
PubMed ID
32864446
Other Identifiers
Notes

Marc Polanik participated in this study as a medical student in the Senior Scholars research program at the University of Massachusetts Medical School.

Funding and Acknowledgements
Corresponding Author
Related Resources
Related Resources
Repository Citation
Rights
© 2020 The Authors. Laryngoscope Investigative Otolaryngology published by Wiley Periodicals, Inc. on behalf of The Triological Society. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.; Attribution-NonCommercial-NoDerivatives 4.0 International