Radiostereometric Analysis of Femoral Head Penetration in Cross-Linked Polyethylene in THR Patients
Authors
Kane, ChristinaPorter, Anthony
Snyder, Benjamin
Walcott, Marie
Aubin, Michelle E.
Drew, Jacob M.
Greene, Meridith
Malchau, Henrik
Bragdon, Charles R.
Ayers, David
Document Type
Poster AbstractPublication Date
2014-05-20
Metadata
Show full item recordAbstract
Background: In the young total hip replacement (THR) population limiting polyethylene liner wear is crucial to preventing premature implant failure. Highly cross-linked ultra-high molecular weight polyethylene (HXLPE) liners were designed to improve wear resistance of polyethylene liners. Radiostereometric analysis (RSA) provides highly precise measurements of liner wear. This study utilized RSA to characterize wear of conventional versus HXLPE liners up to five years following THR. Methods: This IRB-approved, prospective, randomized, blinded study, involved 46 patients with a mean age of 58 and BMI of 30. Each patient was double randomized to receive a conventional or HXLPE liner with an uncemented titanium mesh or tantalum trabecular metal cup. Both liners were prepared from compression-molded GUR 1050 resin without calcium stearate, while HXLPE liners undergo further e-beam irradiation and annealing. At the time of surgery, 1mm tantalum RSA markers were implanted around the liner periphery, femur and periacetabular bone. RSA examinations, Harris Hip, UCLA, WOMAC, SF-36 scores were obtained pre-operatively, post-operatively, at six weeks, six months and annually through five years. Results: All patients had statistically significant improvement in Harris Hip, WOMAC and SF-36 PCS scores following THR with no difference between cohorts. On RSA examination, of titanium shells, HXLPE liners revealed significantly lower femoral head penetration at each follow up except six weeks and six months (p Conclusion: In this young THR population RSA shows significantly less femoral head penetration in the HXLPE liners compared to conventional liners. Novel RSA techniques have been developed to determine polyethylene wear in patients.DOI
10.13028/bhrk-2r43Permanent Link to this Item
http://hdl.handle.net/20.500.14038/27968Notes
Abstract of poster presented at the 2014 UMass Center for Clinical and Translational Science Research Retreat, held on May 20, 2014 at the University of Massachusetts Medical School, Worcester, Mass.
Rights
Copyright the Author(s)Distribution License
http://creativecommons.org/licenses/by-nc-sa/3.0/ae974a485f413a2113503eed53cd6c53
10.13028/bhrk-2r43