We are upgrading the repository! A content freeze is in effect until December 6, 2024. New submissions or changes to existing items will not be allowed during this period. All content already published will remain publicly available for searching and downloading. Updates will be posted in the Website Upgrade 2024 FAQ in the sidebar Help menu. Reach out to escholarship@umassmed.edu with any questions.

Show simple item record

dc.contributor.authorQi, Wenyuan
dc.contributor.authorYang, Yongyi
dc.contributor.authorSong, Chao
dc.contributor.authorWernick, Miles N.
dc.contributor.authorPretorius, P. Hendrik
dc.contributor.authorKing, Michael A
dc.date2022-08-11T08:08:24.000
dc.date.accessioned2022-08-23T15:54:18Z
dc.date.available2022-08-23T15:54:18Z
dc.date.issued2017-08-01
dc.date.submitted2020-08-10
dc.identifier.citation<p>Qi W, Yang Y, Song C, Wernick MN, Pretorius PH, King MA. 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT. IEEE Trans Med Imaging. 2017 Aug;36(8):1626-1635. doi: 10.1109/TMI.2017.2690819. Epub 2017 Apr 4. PMID: 28391190; PMCID: PMC5595423. <a href="https://doi.org/10.1109/TMI.2017.2690819">Link to article on publisher's site</a></p>
dc.identifier.issn0278-0062 (Linking)
dc.identifier.doi10.1109/TMI.2017.2690819
dc.identifier.pmid28391190
dc.identifier.urihttp://hdl.handle.net/20.500.14038/29523
dc.description.abstractCardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated images is reconstructed with respect to a reference respiratory amplitude bin in the respiratory cycle. To combat the challenge of inherent high-imaging noise, we utilize the data counts acquired during the entire respiratory cycle by making use of a motion-compensated scheme, in which both cardiac motion and respiratory motion are taken into account. In the experiments, we first use Monte Carlo simulated imaging data, wherein the ground truth is known for quantitative comparison. We then demonstrate the proposed approach on eight sets of clinical acquisitions, in which the subjects exhibit different degrees of respiratory motion blur. The quantitative evaluation results show that the 4-D reconstruction with respiratory correction could effectively reduce the effect of motion blur and lead to a more accurate reconstruction of the myocardium. The mean-squared error of the myocardium is reduced by 22%, and the left ventricle (LV) resolution is improved by 21%. Such improvement is also demonstrated with the clinical acquisitions, where the motion blur is markedly improved in the reconstructed LV wall and blood pool. The proposed approach is also noted to be effective on correcting the spill-over effect in the myocardium from nearby bowel or liver activities.
dc.language.isoen_US
dc.relation<p><a href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=pubmed&cmd=Retrieve&list_uids=28391190&dopt=Abstract">Link to Article in PubMed</a></p>
dc.relation.urlhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5595423/
dc.subjectImage reconstruction
dc.subjectSingle photon emission computed tomography
dc.subjectLogic gates
dc.subjectMyocardium
dc.subjectData acquisition
dc.subjectSpatiotemporal phenomena
dc.subjectCardiac SPECT
dc.subjectrespiratory binning
dc.subjectcardiac gating
dc.subject4D reconstruction
dc.subjectBiological and Chemical Physics
dc.subjectMedical Biophysics
dc.subjectRadiology
dc.title4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT
dc.typeJournal Article
dc.source.journaltitleIEEE transactions on medical imaging
dc.source.volume36
dc.source.issue8
dc.identifier.legacycoverpagehttps://escholarship.umassmed.edu/faculty_pubs/1746
dc.identifier.contextkey18844217
html.description.abstract<p>Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated images is reconstructed with respect to a reference respiratory amplitude bin in the respiratory cycle. To combat the challenge of inherent high-imaging noise, we utilize the data counts acquired during the entire respiratory cycle by making use of a motion-compensated scheme, in which both cardiac motion and respiratory motion are taken into account. In the experiments, we first use Monte Carlo simulated imaging data, wherein the ground truth is known for quantitative comparison. We then demonstrate the proposed approach on eight sets of clinical acquisitions, in which the subjects exhibit different degrees of respiratory motion blur. The quantitative evaluation results show that the 4-D reconstruction with respiratory correction could effectively reduce the effect of motion blur and lead to a more accurate reconstruction of the myocardium. The mean-squared error of the myocardium is reduced by 22%, and the left ventricle (LV) resolution is improved by 21%. Such improvement is also demonstrated with the clinical acquisitions, where the motion blur is markedly improved in the reconstructed LV wall and blood pool. The proposed approach is also noted to be effective on correcting the spill-over effect in the myocardium from nearby bowel or liver activities.</p>
dc.identifier.submissionpathfaculty_pubs/1746
dc.contributor.departmentDepartment of Radiology, Division of Nuclear Medicine
dc.source.pages1626-1635