Show simple item record

dc.contributor.authorPeterson, Pamela N.
dc.contributor.authorGurwitz, Jerry H.
dc.date2022-08-11T08:09:49.000
dc.date.accessioned2022-08-23T16:44:29Z
dc.date.available2022-08-23T16:44:29Z
dc.date.issued2017-11-09
dc.date.submitted2018-03-27
dc.identifier.citation<p>J Am Heart Assoc. 2017 Nov 9;6(11). pii: e006937. doi: 10.1161/JAHA.117.006937. <a href="https://doi.org/10.1161/JAHA.117.006937">Link to article on publisher's site</a></p>
dc.identifier.issn2047-9980 (Linking)
dc.identifier.doi10.1161/JAHA.117.006937
dc.identifier.pmid29122811
dc.identifier.urihttp://hdl.handle.net/20.500.14038/40510
dc.description<p>Full author list omitted for brevity. For the full list of authors, see article.</p>
dc.description.abstractBACKGROUND: In US clinical practice, many patients who undergo placement of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death receive dual-chamber devices. The superiority of dual-chamber over single-chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compare risk of adverse outcomes, including inappropriate shocks, between single- and dual-chamber ICDs for primary prevention. METHODS AND RESULTS: We identified patients receiving a single- or dual-chamber ICD for primary prevention who did not have an indication for pacing from 15 hospitals within 7 integrated health delivery systems in the Longitudinal Study of Implantable Cardioverter-Defibrillators from 2006 to 2009. The primary outcome was time to first inappropriate shock. ICD shocks were adjudicated for appropriateness. Other outcomes included all-cause hospitalization, heart failure hospitalization, and death. Patient, clinician, and hospital-level factors were accounted for using propensity score weighting methods. Among 1042 patients without pacing indications, 54.0% (n=563) received a single-chamber device and 46.0% (n=479) received a dual-chamber device. In a propensity-weighted analysis, device type was not significantly associated with inappropriate shock (hazard ratio, 0.91; 95% confidence interval, 0.59-1.38 [P=0.65]), all-cause hospitalization (hazard ratio, 1.03; 95% confidence interval, 0.87-1.21 [P=0.76]), heart failure hospitalization (hazard ratio, 0.93; 95% confidence interval, 0.72-1.21 [P=0.59]), or death (hazard ratio, 1.19; 95% confidence interval, 0.93-1.53 [P=0.17]). CONCLUSIONS: Among patients who received an ICD for primary prevention without indications for pacing, dual-chamber devices were not associated with lower risk of inappropriate shock or differences in hospitalization or death compared with single-chamber devices. This study does not justify the use of dual-chamber devices to minimize inappropriate shocks.
dc.language.isoen_US
dc.relation<p><a href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=pubmed&cmd=Retrieve&list_uids=29122811&dopt=Abstract">Link to Article in PubMed</a></p>
dc.rightsCopyright 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subjectdefibrillator shocks
dc.subjectimplantable cardioverter‐defibrillators
dc.subjectoutcomes research
dc.subjectCardiology
dc.subjectCardiovascular Diseases
dc.subjectClinical Epidemiology
dc.subjectEpidemiology
dc.subjectEquipment and Supplies
dc.titleComparison of Inappropriate Shocks and Other Health Outcomes Between Single- and Dual-Chamber Implantable Cardioverter-Defibrillators for Primary Prevention of Sudden Cardiac Death: Results From the Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter-Defibrillators
dc.typeJournal Article
dc.source.journaltitleJournal of the American Heart Association
dc.source.volume6
dc.source.issue11
dc.identifier.legacyfulltexthttps://escholarship.umassmed.edu/cgi/viewcontent.cgi?article=4324&amp;context=oapubs&amp;unstamped=1
dc.identifier.legacycoverpagehttps://escholarship.umassmed.edu/oapubs/3313
dc.identifier.contextkey11856461
refterms.dateFOA2022-08-23T16:44:29Z
html.description.abstract<p>BACKGROUND: In US clinical practice, many patients who undergo placement of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death receive dual-chamber devices. The superiority of dual-chamber over single-chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compare risk of adverse outcomes, including inappropriate shocks, between single- and dual-chamber ICDs for primary prevention.</p> <p>METHODS AND RESULTS: We identified patients receiving a single- or dual-chamber ICD for primary prevention who did not have an indication for pacing from 15 hospitals within 7 integrated health delivery systems in the Longitudinal Study of Implantable Cardioverter-Defibrillators from 2006 to 2009. The primary outcome was time to first inappropriate shock. ICD shocks were adjudicated for appropriateness. Other outcomes included all-cause hospitalization, heart failure hospitalization, and death. Patient, clinician, and hospital-level factors were accounted for using propensity score weighting methods. Among 1042 patients without pacing indications, 54.0% (n=563) received a single-chamber device and 46.0% (n=479) received a dual-chamber device. In a propensity-weighted analysis, device type was not significantly associated with inappropriate shock (hazard ratio, 0.91; 95% confidence interval, 0.59-1.38 [P=0.65]), all-cause hospitalization (hazard ratio, 1.03; 95% confidence interval, 0.87-1.21 [P=0.76]), heart failure hospitalization (hazard ratio, 0.93; 95% confidence interval, 0.72-1.21 [P=0.59]), or death (hazard ratio, 1.19; 95% confidence interval, 0.93-1.53 [P=0.17]).</p> <p>CONCLUSIONS: Among patients who received an ICD for primary prevention without indications for pacing, dual-chamber devices were not associated with lower risk of inappropriate shock or differences in hospitalization or death compared with single-chamber devices. This study does not justify the use of dual-chamber devices to minimize inappropriate shocks.</p>
dc.identifier.submissionpathoapubs/3313
dc.contributor.departmentDepartment of Medicine
dc.contributor.departmentMeyers Primary Care Institute
dc.source.pagese006937


Files in this item

Thumbnail
Name:
e006937.full.pdf
Size:
817.4Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record

Copyright 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Except where otherwise noted, this item's license is described as Copyright 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.