Show simple item record

dc.contributor.authorMarturano, Joseph E.
dc.contributor.authorCleveland, Benjamin C.
dc.contributor.authorBryne, Melissa A.
dc.contributor.authorO'Connell, Shannon L.
dc.contributor.authorWixted, John J.
dc.contributor.authorBilliar, Kristen L.
dc.date2022-08-11T08:10:08.000
dc.date.accessioned2022-08-23T16:56:55Z
dc.date.available2022-08-23T16:56:55Z
dc.date.issued2008-04-04
dc.date.submitted2011-05-26
dc.identifier.citationJ Biomech. 2008;41(6):1222-8. Epub 2008 Apr 1. <a href="http://dx.doi.org/10.1016/j.jbiomech.2008.01.029">Link to article on publisher's site</a>
dc.identifier.issn0021-9290 (Linking)
dc.identifier.doi10.1016/j.jbiomech.2008.01.029
dc.identifier.pmid18384794
dc.identifier.urihttp://hdl.handle.net/20.500.14038/43034
dc.description.abstractMurine models are commonly used to investigate bone healing and test new treatments before human trials. Our objective was to design an improved murine femur fracture device and determine optimal mass and velocity settings for maximal likelihood of transverse fracture. Fracture reproducibility was maximized using an adjustable kinetic energy level, a novel mouse positioning system and an electromagnet striker release assembly. Sixty wild-type mice of 8-12-week-old male and female with a weight of 26.4+/-6.1g were subjected to an experimental postmortem fracture in the left and right femur (n=120) using variable kinetic energy inputs. A best-fit prediction equation for transverse fracture was developed using multivariate linear regression. Transverse fracture was shown to correlate most highly with kinetic energy with a maximum likelihood at mv2=292 where m is mass (g) and v is velocity (m/s). Model validation with a group of 134 anesthetized C57BL/6 mice resulted in a favorable transverse fracture rate of 85.8%. Simple modifications to existing fracture devices can improve accuracy and reproducibility. The results may assist researchers studying the effects of genetic modifications and novel treatments on boney healing in murine femur fracture models. Maintaining kinetic energy parameters within suggested ranges may also aid in ensuring accuracy and reproducibility.
dc.language.isoen_US
dc.relation<a href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=pubmed&cmd=Retrieve&list_uids=18384794&dopt=Abstract">Link to Article in PubMed</a>
dc.relation.urlhttp://dx.doi.org/10.1016/j.jbiomech.2008.01.029
dc.subjectAnimals
dc.subjectEquipment Design
dc.subjectFemale
dc.subject*Femoral Fractures
dc.subjectFracture Healing
dc.subjectMale
dc.subjectMice
dc.subjectModels, Animal
dc.subjectReproducibility of Results
dc.subjectOrthopedics
dc.subjectRehabilitation and Therapy
dc.titleAn improved murine femur fracture device for bone healing studies
dc.typeJournal Article
dc.source.journaltitleJournal of biomechanics
dc.source.volume41
dc.source.issue6
dc.identifier.legacycoverpagehttps://escholarship.umassmed.edu/ortho_pp/43
dc.identifier.contextkey2032282
html.description.abstract<p>Murine models are commonly used to investigate bone healing and test new treatments before human trials. Our objective was to design an improved murine femur fracture device and determine optimal mass and velocity settings for maximal likelihood of transverse fracture. Fracture reproducibility was maximized using an adjustable kinetic energy level, a novel mouse positioning system and an electromagnet striker release assembly. Sixty wild-type mice of 8-12-week-old male and female with a weight of 26.4+/-6.1g were subjected to an experimental postmortem fracture in the left and right femur (n=120) using variable kinetic energy inputs. A best-fit prediction equation for transverse fracture was developed using multivariate linear regression. Transverse fracture was shown to correlate most highly with kinetic energy with a maximum likelihood at mv2=292 where m is mass (g) and v is velocity (m/s). Model validation with a group of 134 anesthetized C57BL/6 mice resulted in a favorable transverse fracture rate of 85.8%. Simple modifications to existing fracture devices can improve accuracy and reproducibility. The results may assist researchers studying the effects of genetic modifications and novel treatments on boney healing in murine femur fracture models. Maintaining kinetic energy parameters within suggested ranges may also aid in ensuring accuracy and reproducibility.</p>
dc.identifier.submissionpathortho_pp/43
dc.contributor.departmentDepartment of Orthopedics and Physical Rehabilitation
dc.source.pages1222-8


Files in this item

Thumbnail
Name:
Publisher version

This item appears in the following Collection(s)