Show simple item record

dc.contributor.authorAuerbach, Marc
dc.contributor.authorWhitfill, Travis
dc.contributor.authorGawel, Marcie
dc.contributor.authorKessler, David
dc.contributor.authorWalsh, Barbara M.
dc.contributor.authorGangadharan, Sandeep
dc.contributor.authorHamilton, Melinda Fiedor.
dc.contributor.authorSchultz, Brian
dc.contributor.authorNishisaki, Akira
dc.contributor.authorTay, Khoon-Yen
dc.contributor.authorLavoie, Megan
dc.contributor.authorKatznelson, Jessica
dc.contributor.authorDudas, Robert
dc.contributor.authorBaird, Janette
dc.contributor.authorNadkarni, Vinay
dc.contributor.authorBrown, Linda
dc.date2022-08-11T08:10:14.000
dc.date.accessioned2022-08-23T17:00:23Z
dc.date.available2022-08-23T17:00:23Z
dc.date.issued2016-10-01
dc.date.submitted2016-11-16
dc.identifier.citationJAMA Pediatr. 2016 Oct 1;170(10):987-994. doi: 10.1001/jamapediatrics.2016.1550. <a href="http://dx.doi.org/10.1001/jamapediatrics.2016.1550">Link to article on publisher's site</a>
dc.identifier.issn2168-6203 (Linking)
dc.identifier.doi10.1001/jamapediatrics.2016.1550
dc.identifier.pmid27570926
dc.identifier.urihttp://hdl.handle.net/20.500.14038/43788
dc.description.abstractImportance: The quality of pediatric resuscitative care delivered across the spectrum of emergency departments (EDs) in the United States is poorly described. In a recent study, more than 4000 EDs completed the Pediatric Readiness Survey (PRS); however, the correlation of PRS scores with the quality of simulated or real patient care has not been described. Objective: To measure and compare the quality of resuscitative care delivered to simulated pediatric patients across a spectrum of EDs and to examine the correlation of PRS scores with quality measures. Design, Setting, and Participants: This prospective multicenter cohort study evaluated 58 interprofessional teams in their native pediatric or general ED resuscitation bays caring for a series of 3 simulated critically ill patients (sepsis, seizure, and cardiac arrest). Main Outcomes and Measures: A composite quality score (CQS) was measured as the sum of 4 domains: (1) adherence to sepsis guidelines, (2) adherence to cardiac arrest guidelines, (3) performance on seizure resuscitation, and (4) teamwork. Pediatric Readiness Survey scores and health care professional demographics were collected as independent data. Correlations were explored between CQS and individual domain scores with PRS. Results: Overall, 58 teams from 30 hospitals participated (8 pediatric EDs [PEDs], 22 general EDs [GEDs]). The mean CQS was 71 (95% CI, 68-75); PEDs had a higher mean CQS (82; 95% CI, 79-85) vs GEDs (66; 95% CI, 63-69) and outperformed GEDs in all domains. However, when using generalized estimating equations to estimate CQS controlling for clustering of the data, PED status did not explain a higher CQS (beta = 4.28; 95% CI, -4.58 to 13.13) while the log of pediatric patient volume did explain a higher CQS (beta = 9.57; 95% CI, 2.64-16.49). The correlation of CQS to PRS was moderate (r = 0.51; P < .001). The correlation was weak for cardiac arrest (r = 0.24; P = .07), weak for sepsis (rho = 0.45; P < .001) and seizure (rho = 0.43; P = .001), and strong for teamwork (rho = 0.71; P < .001). Conclusions and Relevance: This multicenter study noted significant differences in the quality of simulated pediatric resuscitative care across a spectrum of EDs. The CQS was higher in PEDs compared with GEDs. However, when controlling for pediatric patient volume and other variables in a multivariable model, PED status does not explain a higher CQS while pediatric patient volume does. The correlation of the PRS was moderate for simulation-based measures of quality.
dc.language.isoen_US
dc.relation<a href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=pubmed&cmd=Retrieve&list_uids=27570926&dopt=Abstract">Link to Article in PubMed</a>
dc.relation.urlhttp://dx.doi.org/10.1001/jamapediatrics.2016.1550
dc.rightsPublisher PDF posted after 12 months as allowed by the publisher's author rights policy at http://jamanetwork.com/journals/jamapediatrics/pages/instructions-for-authors#SecDepositingResearchArticlesinApprovedPublicRepositories.
dc.subjectEmergency Medicine
dc.subjectPediatrics
dc.titleDifferences in the Quality of Pediatric Resuscitative Care Across a Spectrum of Emergency Departments
dc.typeJournal Article
dc.source.journaltitleJAMA pediatrics
dc.source.volume170
dc.source.issue10
dc.identifier.legacyfulltexthttps://escholarship.umassmed.edu/cgi/viewcontent.cgi?article=1098&amp;context=peds_pp&amp;unstamped=1
dc.identifier.legacycoverpagehttps://escholarship.umassmed.edu/peds_pp/99
dc.legacy.embargo2017-10-01T00:00:00-07:00
dc.identifier.contextkey9383601
refterms.dateFOA2022-08-23T17:00:24Z
html.description.abstract<p>Importance: The quality of pediatric resuscitative care delivered across the spectrum of emergency departments (EDs) in the United States is poorly described. In a recent study, more than 4000 EDs completed the Pediatric Readiness Survey (PRS); however, the correlation of PRS scores with the quality of simulated or real patient care has not been described.</p> <p>Objective: To measure and compare the quality of resuscitative care delivered to simulated pediatric patients across a spectrum of EDs and to examine the correlation of PRS scores with quality measures.</p> <p>Design, Setting, and Participants: This prospective multicenter cohort study evaluated 58 interprofessional teams in their native pediatric or general ED resuscitation bays caring for a series of 3 simulated critically ill patients (sepsis, seizure, and cardiac arrest).</p> <p>Main Outcomes and Measures: A composite quality score (CQS) was measured as the sum of 4 domains: (1) adherence to sepsis guidelines, (2) adherence to cardiac arrest guidelines, (3) performance on seizure resuscitation, and (4) teamwork. Pediatric Readiness Survey scores and health care professional demographics were collected as independent data. Correlations were explored between CQS and individual domain scores with PRS.</p> <p>Results: Overall, 58 teams from 30 hospitals participated (8 pediatric EDs [PEDs], 22 general EDs [GEDs]). The mean CQS was 71 (95% CI, 68-75); PEDs had a higher mean CQS (82; 95% CI, 79-85) vs GEDs (66; 95% CI, 63-69) and outperformed GEDs in all domains. However, when using generalized estimating equations to estimate CQS controlling for clustering of the data, PED status did not explain a higher CQS (beta = 4.28; 95% CI, -4.58 to 13.13) while the log of pediatric patient volume did explain a higher CQS (beta = 9.57; 95% CI, 2.64-16.49). The correlation of CQS to PRS was moderate (r = 0.51; P < .001). The correlation was weak for cardiac arrest (r = 0.24; P = .07), weak for sepsis (rho = 0.45; P < .001) and seizure (rho = 0.43; P = .001), and strong for teamwork (rho = 0.71; P < .001).</p> <p>Conclusions and Relevance: This multicenter study noted significant differences in the quality of simulated pediatric resuscitative care across a spectrum of EDs. The CQS was higher in PEDs compared with GEDs. However, when controlling for pediatric patient volume and other variables in a multivariable model, PED status does not explain a higher CQS while pediatric patient volume does. The correlation of the PRS was moderate for simulation-based measures of quality.</p>
dc.identifier.submissionpathpeds_pp/99
dc.contributor.departmentDepartment of Pediatrics, Division of Emergency Medicine
dc.source.pages987-994


Files in this item

Thumbnail
Name:
JAMApoi160045.pdf
Size:
239.2Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record