Show simple item record

dc.contributor.authorChristensen, Ryan G.
dc.contributor.authorGupta, Ankit
dc.contributor.authorZuo, Zheng
dc.contributor.authorSchriefer, Lawrence A.
dc.contributor.authorWolfe, Scot A.
dc.contributor.authorStormo, Gary D.
dc.date2022-08-11T08:10:15.000
dc.date.accessioned2022-08-23T17:01:08Z
dc.date.available2022-08-23T17:01:08Z
dc.date.issued2011-07-01
dc.date.submitted2011-08-01
dc.identifier.citationNucleic Acids Res. 2011 Jul 1;39(12):e83. Epub 2011 Apr 20. <a href="http://dx.doi.org/10.1093/nar/gkr239">Link to article on publisher's site</a>
dc.identifier.issn0305-1048 (Linking)
dc.identifier.doi10.1093/nar/gkr239
dc.identifier.pmid21507886
dc.identifier.urihttp://hdl.handle.net/20.500.14038/43942
dc.description.abstractWe examine the use of high-throughput sequencing on binding sites recovered using a bacterial one-hybrid (B1H) system and find that improved models of transcription factor (TF) binding specificity can be obtained compared to standard methods of sequencing a small subset of the selected clones. We can obtain even more accurate binding models using a modified version of B1H selection method with constrained variation (CV-B1H). However, achieving these improved models using CV-B1H data required the development of a new method of analysis-GRaMS (Growth Rate Modeling of Specificity)-that estimates bacterial growth rates as a function of the quality of the recognition sequence. We benchmark these different methods of motif discovery using Zif268, a well-characterized C(2)H(2) zinc-finger TF on both a 28 bp randomized library for the standard B1H method and on 6 bp randomized library for the CV-B1H method for which 45 different experimental conditions were tested: five time points and three different IPTG and 3-AT concentrations. We find that GRaMS analysis is robust to the different experimental parameters whereas other analysis methods give widely varying results depending on the conditions of the experiment. Finally, we demonstrate that the CV-B1H assay can be performed in liquid media, which produces recognition models that are similar in quality to sequences recovered from selection on solid media.
dc.language.isoen_US
dc.relation<a href="http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=pubmed&cmd=Retrieve&list_uids=21507886&dopt=Abstract">Link to Article in PubMed</a>
dc.rights© The Author(s) 2011. Published by Oxford University Press. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/2.5), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.subjectTranscription Factors
dc.subjectTwo-Hybrid System Techniques
dc.subjectHigh-Throughput Screening Assays
dc.subjectGenetics and Genomics
dc.titleA modified bacterial one-hybrid system yields improved quantitative models of transcription factor specificity
dc.typeJournal Article
dc.source.journaltitleNucleic acids research
dc.source.volume39
dc.source.issue12
dc.identifier.legacyfulltexthttps://escholarship.umassmed.edu/cgi/viewcontent.cgi?article=1153&amp;context=pgfe_pp&amp;unstamped=1
dc.identifier.legacycoverpagehttps://escholarship.umassmed.edu/pgfe_pp/153
dc.identifier.contextkey2124687
refterms.dateFOA2022-08-23T17:01:08Z
html.description.abstract<p>We examine the use of high-throughput sequencing on binding sites recovered using a bacterial one-hybrid (B1H) system and find that improved models of transcription factor (TF) binding specificity can be obtained compared to standard methods of sequencing a small subset of the selected clones. We can obtain even more accurate binding models using a modified version of B1H selection method with constrained variation (CV-B1H). However, achieving these improved models using CV-B1H data required the development of a new method of analysis-GRaMS (Growth Rate Modeling of Specificity)-that estimates bacterial growth rates as a function of the quality of the recognition sequence. We benchmark these different methods of motif discovery using Zif268, a well-characterized C(2)H(2) zinc-finger TF on both a 28 bp randomized library for the standard B1H method and on 6 bp randomized library for the CV-B1H method for which 45 different experimental conditions were tested: five time points and three different IPTG and 3-AT concentrations. We find that GRaMS analysis is robust to the different experimental parameters whereas other analysis methods give widely varying results depending on the conditions of the experiment. Finally, we demonstrate that the CV-B1H assay can be performed in liquid media, which produces recognition models that are similar in quality to sequences recovered from selection on solid media.</p>
dc.identifier.submissionpathpgfe_pp/153
dc.contributor.departmentDepartment of Biochemistry and Molecular Pharmacology
dc.contributor.departmentProgram in Gene Function and Expression
dc.source.pagese83


Files in this item

Thumbnail
Name:
Nucl._Acids_Res._2011_Christen ...
Size:
2.032Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record