Feasibility and accuracy of UF/NCI phantoms and Monte Carlo retrospective dosimetry in children treated on National Wilms Tumor Study protocols
Authors
Kalapurakal, John A.Gopalakrishnan, Mahesh
Mille, Matthew
Helenowski, Irene
Peterson, Susan
Rigsby, Cynthia
Laurie, Fran
Jung, Jae Won
Fitzgerald, Thomas J.
Lee, Choonsik
Document Type
Journal ArticlePublication Date
2018-12-01Keywords
Monte Carlo dosimetrydosimetry
epidemiology
phantom model
radiation
Hemic and Lymphatic Diseases
Neoplasms
Oncology
Pediatrics
Radiation Medicine
Metadata
Show full item recordAbstract
PURPOSE: This pilot study was done to determine the feasibility and accuracy of University of Florida/National Cancer Institute (UF/NCI) phantoms and Monte Carlo (MC) retrospective dosimetry and had two aims: (1) to determine the anatomic accuracy of UF/NCI phantoms by comparing 3D organ doses in National Wilms Tumor Study (NWTS) patient-matched UF/NCI phantoms to organ doses in corresponding patient-matched CT scans and (2) to compare infield and out-of-field organ dosimetry using two dosimetry methods-standard radiation therapy (RT) treatment planning systems (TPS) and MC dosimetry in these two anatomic models. METHODS: Twenty NWTS patient-matched Digital Imaging and Communications in Medicine (DICOM) files of UF/NCI phantoms and CT scans were imported into the Pinnacle RT TPS. The NWTS RT fields (whole abdomen, flank, whole lung, or a combination) and RT doses (10-45 Gy) were reconstructed in both models. Both TPS and MC dose calculations were performed. For aim 1, the mean doses to the heart, kidney, thyroid gland, testes, and ovaries using TPS and MC in both models were statistically compared. For aim 2, the TPS and MC dosimetry for these organs in both models were statistically compared. RESULTS: For aim 1, there was no significant difference between phantom and CT scan dosimetry for any of the organs using either TPS or MC dosimetry. For aim 2, there was a significant difference between TPS and MC dosimetry for both CT scan and phantoms for all organs. Although the doses for infield organs were similar for both TPS and MC, the doses for near-field and out-of-field organs were consistently higher for 90% to 100% of MC doses; however, the absolute dose difference was small (Gy). CONCLUSIONS: This pilot study has demonstrated that the patient-matched UF/NCI phantoms together with MC dosimetry is an accurate model for performing retrospective 3D dosimetry in large-scale epidemiology studies such as the NWTS.Source
Pediatr Blood Cancer. 2018 Dec;65(12):e27395. doi: 10.1002/pbc.27395. Epub 2018 Aug 12. Link to article on publisher's website
DOI
10.1002/pbc.27395Permanent Link to this Item
http://hdl.handle.net/20.500.14038/47902PubMed ID
30101560Related Resources
ae974a485f413a2113503eed53cd6c53
10.1002/pbc.27395