Prescription dose evaluation for APBI with noninvasive image-guided breast brachytherapy using equivalent uniform dose
Name:
Publisher version
View Source
Access full-text PDFOpen Access
View Source
Check access options
Check access options
Authors
Leonard, Kara LynneRivard, Mark J.
Wazer, David E.
Hiatt, Jessica R.
Sioshansi, Shirin
DiPetrillo, Thomas A.
Hepel, Jaroslaw T.
UMass Chan Affiliations
Department of Radiation OncologyDocument Type
Journal ArticlePublication Date
2015-07-01
Metadata
Show full item recordAbstract
PURPOSE: Noninvasive image-guided breast brachytherapy (NIBB) is an attractive novel approach to deliver accelerated partial breast irradiation (APBI). Calculations of equivalent uniform dose (EUD) were performed to identify the appropriate APBI dose for this technique. METHODS AND MATERIALS: APBI plans were developed for 15 patients: five with three-dimensional conformal APBI (3D-CRT), five with multi-lumen intracavitary balloons (m-IBB), and five simulating NIBB treatment. Prescription doses of 34.0 and 38.5 Gy were delivered in 10 fractions for m-IBB and 3D-CRT, respectively. Prescription doses ranging from 34.0 to 38.5 Gy were considered for NIBB. Dose-volume histogram data from all 3D-CRT, m-IBB, and NIBB plans were used to calculate the biologically effective EUD and corresponding EUD to the PTV_eval using the following equation: EUD = EUBED/(n [1 + EUD/alpha/beta]). An alpha/beta value of 4.6 Gy was assumed for breast tumor. EUD for varying NIBB prescription doses were compared with EUD values for the other APBI techniques. RESULTS: Mean PTV_eval volume was largest for 3D-CRT (372.9 cm(3)) and was similar for NIBB and m-IBB (88.7 and 87.2 cm(3), respectively). The EUD value obtained by prescribing 38.5 Gy with 3D-CRT APBI was 38.6 Gy. The EUD value of 34.0 Gy prescribed with m-IBB was 34.4 Gy. EUD values for NIBB ranged from 33.9 to 38.2 Gy for prescription doses ranging from 34.0 to 38.5 Gy. CONCLUSIONS: Using EUD calculations to compare APBI techniques and treatment doses, a prescription dose of 36.0 Gy in 10 fractions using NIBB has a comparable biologic equivalent dose to other established brachytherapy techniques.Source
Brachytherapy. 2015 Jul-Aug;14(4):496-501. doi: 10.1016/j.brachy.2015.03.007. Epub 2015 Apr 18. Link to article on publisher's siteDOI
10.1016/j.brachy.2015.03.007Permanent Link to this Item
http://hdl.handle.net/20.500.14038/47970PubMed ID
25900392Related Resources
Link to Article in PubMedae974a485f413a2113503eed53cd6c53
10.1016/j.brachy.2015.03.007