Improved Performance of a Multipinhole SPECT for DAT Imaging by Increasing Number of Pinholes at the Expense of Increased Multiplexing
Authors
Konik, ArdaZeraatkar, Navid
Kalluri, Kesava S.
Auer, Benjamin
Fromme, Timothy J.
He, Yulun
May, Micaehla
Furenlid, Lars R.
Kuo, Phillip H.
King, Michael A.
UMass Chan Affiliations
Department of RadiologyDocument Type
Journal ArticlePublication Date
2021-11-01Keywords
MultiplexingSBR
SPECT
dopamine transporter imaging
multi-pinhole
sampling
Analytical, Diagnostic and Therapeutic Techniques and Equipment
Bioimaging and Biomedical Optics
Physics
Radiation Medicine
Radiology
Metadata
Show full item recordAbstract
SPECT imaging of dopamine transporters (DAT) in the brain is a widely utilized study to improve the diagnosis of Parkinsonian syndromes, where conventional (parallel-hole and fan-beam) collimators on dual-head scanners are commonly employed. We have designed a multi-pinhole (MPH) collimator to improve the performance of DAT imaging. The MPH collimator focuses on the striatum and hence offers a better trade-off for sensitivity and spatial resolution than the conventional collimators within this clinically most relevant region for DAT imaging. Our original MPH design consisted of 9 pinholes with a background-to-striatal (Bkg/Str) projection multiplexing of 1% only. In this simulation study, we investigated whether further improvements in the performance of MPH imaging could be obtained by increasing the number of pinholes, hence by enhancing the sensitivity and sampling, despite the ambiguity in reconstructing images due to increased multiplexing. We performed analytic simulations of the MPH configurations with 9, 13, and 16 pinholes (aperture diameters: 4-6mm) using a digital phantom modeling DAT imaging. Our quantitative analyses indicated that using 13 (Bkg/Str: 12%) and 16 (Bkg/Str: 22%) pinholes provided better performance than the original 9-pinhole configuration for the acquisition with 2 or 4 angular views, but a similar performance with 8 and 16 views.Source
Könik A, Zeraatkar N, Kalluri KS, Auer B, Fromme TJ, He Y, May M, Furenlid LR, Kuo PH, King MA. Improved Performance of a Multipinhole SPECT for DAT Imaging by Increasing Number of Pinholes at the Expense of Increased Multiplexing. IEEE Trans Radiat Plasma Med Sci. 2021 Nov;5(6):817-825. doi: 10.1109/trpms.2020.3035626. Epub 2020 Nov 3. PMID: 34746540; PMCID: PMC8568304. Link to article on publisher's site
DOI
10.1109/trpms.2020.3035626Permanent Link to this Item
http://hdl.handle.net/20.500.14038/48567PubMed ID
34746540Related Resources
ae974a485f413a2113503eed53cd6c53
10.1109/trpms.2020.3035626