Flow Diverter Reconstruction of Internal Carotid Artery (Loop) Dissections with or without Associated Pseudoaneurysms
Name:
Publisher version
View Source
Access full-text PDFOpen Access
View Source
Check access options
Check access options
Authors
Kuhn, Anna L.Singh, Jasmeet
Massari, Francesco
de Macedo Rodrigues, Katyucia
Gounis, Matthew J
Puri, Ajit S
UMass Chan Affiliations
RadiologyDocument Type
Journal ArticlePublication Date
2022-02-22Keywords
Carotid stentDissection
Flow diverter
Internal carotid artery
Pseudoaneurysm
Stroke
Cardiovascular Diseases
Nervous System Diseases
Neurology
Neurosurgery
Radiology
Metadata
Show full item recordAbstract
OBJECTIVE: Endovascular treatment of cervical internal carotid artery (ICA) loop dissections in acute stroke interventions can be challenging. Flow diverters can effectively reconstruct vessel loops and treat the injured vessel and provide a safe conduit for intracranial catheterization. METHODS: We retrospectively reviewed our neurointerventional database and identified all patients with ICA loop dissections treated with flow diverters in the acute setting between August 2016 and September 2020. Patient demographics, procedural data, imaging follow-up results, and clinical outcome information were collected. RESULTS: Seven patients with a mean age of 62 years (range: 43-85 years) who underwent reconstruction of an ICA (loop) dissection with flow diverters were included. Four ICA dissections were treated with the Surpass Streamline flow diverter and 3 with the Pipeline embolization device. All cases were technically successful. All stroke cases achieved intracranial flow > /=thrombolysis in cerebral infarction 2B. Observed intracranial hemorrhages were all asymptomatic. All cases showed patent flow diverter(s) with or without (carotid) stent(s) on follow-up imaging. Semielectively treated patients did not show a change from baseline modified Rankin scale related to the procedure. Patients with acute stroke had a modified Rankin scale < /=2 in 4 of 5 cases (80%) at 3 months. Two patients died due to medical issues unrelated to the procedures. No patient showed new or recurrent symptoms. CONCLUSION: Use of flow diverters, in some cases in conjunction with (carotid) stents, is an effective treatment option for cervical carotid artery (loop) dissections.Source
Kühn AL, Singh J, Massari F, de Macedo Rodrigues K, Gounis MJ, Puri AS. Flow Diverter Reconstruction of Internal Carotid Artery (Loop) Dissections with or without Associated Pseudoaneurysms. World Neurosurg. 2022 Feb 22:S1878-8750(22)00220-0. doi: 10.1016/j.wneu.2022.02.073. Epub ahead of print. PMID: 35217230. Link to article on publisher's site
DOI
10.1016/j.wneu.2022.02.073Permanent Link to this Item
http://hdl.handle.net/20.500.14038/48636PubMed ID
35217230Related Resources
ae974a485f413a2113503eed53cd6c53
10.1016/j.wneu.2022.02.073