We are upgrading the repository! The content freeze has been extended to December 11, 2024, when we expect the new repository to become available. New submissions or changes to existing items will not be allowed until after the new website goes live. All content already published will remain publicly available for searching and downloading. Updates will be posted in the Website Upgrade 2024 FAQ in the sidebar Help menu. Reach out to escholarship@umassmed.edu with any questions.
Measuring Satisfaction With Upper Limb Prostheses: Orthotics and Prosthetics User Survey Revision That Includes Issues of Concern to Women
Name:
Publisher version
View Source
Access full-text PDFOpen Access
View Source
Check access options
Check access options
UMass Chan Affiliations
Population and Quantitative Health SciencesDocument Type
Journal ArticlePublication Date
2022-06-12Keywords
Factor analysisPatient reported outcome measures
Patient satisfaction
Prostheses
Upper extremity
Metadata
Show full item recordAbstract
Objective: To (1) modify the Orthotics and Prosthetics User Survey (OPUS) Client Satisfaction with Device (CSD) instrument to incorporate issues of concern to women and (2) evaluate measure's structural and concurrent validity and reliability in persons with upper limb amputation (ULA). Design: Cross-sectional survey study with retest after 2 weeks. Exploratory factor analysis (EFA), confirmatory factor analysis (CFA), and Rasch analyses were used to select items and examine differential item functioning, range of coverage, and person and item reliability. Test-retest reliability was evaluated with intraclass correlation coefficients. Pearson correlations were used to estimate associations with other prosthesis satisfaction measures. Setting: Telephone administered survey. Participants: Convenience sample of 468 participants in the US (N=468; 19.9% women) with ULA, including a 50-person retest subsample (4% female). Interventions: Not applicable. Main outcome measures: Modified OPUS CSD. Results: EFA suggested 3 subscales: Comfort, Appearance, and Utility. CFA found acceptable model fit. After dropping items with poor fit and high pairwise correlations in Rasch partial credit models, CFA model fit indices were acceptable (comparative fit index=0.959, Tucker-Lewis Index=0.954, root mean square error of approximation=0.082). Rasch person reliability was 0.62 (Utility), 0.77 (Appearance), and 0.82 (Comfort). Cronbach α was 0.81, 87, and 0.71 for Comfort and Appearance, and Utility subscales, respectively. Correlations between the modified CSD, the original CSD, and the Trinity Amputation and Prosthesis Experience Satisfaction Scale were 0.54-0.94. Conclusions: We identified 3 subscales: Comfort (6 items), Appearance (8 items), and Utility (4 items) with 7 new items identified as important to women. The subscales demonstrate evidence of sound concurrent structural and test-retest reliability and concurrent validity. The Appearance and Comfort subscales have good reliability for group-level use in clinical and research applications, whereas the Utility subscale had poor to fair person reliability but excellent item reliability.Source
Resnik LJ, Borgia ML, Clark MA, Heinemann AW, Ni P. Measuring Satisfaction With Upper Limb Prostheses: Orthotics and Prosthetics User Survey Revision That Includes Issues of Concern to Women. Arch Phys Med Rehabil. 2022 Jun 12:S0003-9993(22)00418-X. doi: 10.1016/j.apmr.2022.05.008. Epub ahead of print. PMID: 35705138.DOI
10.1016/j.apmr.2022.05.008Permanent Link to this Item
http://hdl.handle.net/20.500.14038/51296PubMed ID
35705138Rights
Published by Elsevier Inc.ae974a485f413a2113503eed53cd6c53
10.1016/j.apmr.2022.05.008